A completed motor test report can be accidentally changed when a technician reopens a file, saves over the wrong version, or uses a shared test-bench PC account. To prevent edits to completed motor test reports, set up access so staff can create and review reports without silently changing finalized results. Then define how an authorized person can document a correction while preserving the original.
This is a practical change-control approach, not a one-size-fits-all compliance rule. Consider your shop’s customer and contract requirements, test software capabilities, and the way reports move from the test bench to the job record.
Separate report creation from final approval
Start by deciding who can create, review, finalize, reopen, and correct a report. These roles do not have to be assigned to the same person. For example, technicians may create and view reports, while a designated reviewer approves finalization and handles requests to correct a finalized report.
Keep permissions tied to job responsibilities. Someone who needs to run a test does not necessarily need permission to change a completed report. Likewise, an employee who needs to read past results should not need broad access to the report archive.
Write down who is authorized to reopen or correct a report and how a technician requests a change. The process should be usable on a busy shop floor, so staff know where to raise a concern and who makes the decision. If your shop has customer or contract requirements for record changes, account for those before setting the workflow.

Use individual accounts on the test-bench PC
Give each technician a separate user account rather than relying on a shared login. Individual accounts make it easier to connect actions to the person who performed them and to remove access when someone changes roles or leaves. A shared account may make a log entry less useful because it identifies the account, not necessarily the person at the bench.
Assign only the access each role needs. A technician might be able to run the test software and save a draft report, while a reviewer has the added ability to finalize a report or authorize a correction. Keep administrative access limited to people who need it for system management.
Also check how the test application handles logins. A PC can have separate Windows accounts while the test software itself uses a shared account, or the application may save files under a service account. In those cases, file activity may not identify which employee made a change. Review both the operating system and application access, and use the application’s own audit or user controls when available.
Make finalized reports read-only in more than one place
Once a report is finalized, store it in a location where ordinary technician accounts can view it but cannot overwrite or delete it. Folder permissions can help enforce that separation. A read-only file setting may be convenient, but it should not be the only safeguard: users or applications with broader permissions may still be able to change the file.
Confirm that the test software cannot bypass the intended restriction. Check whether it can overwrite a finalized file, save a new report using the same name, or modify files through a shared account. If the software cannot support a reliable finalized state, consider a controlled export or transfer step into a protected report folder, subject to how the software and your workflow operate.
Make the status clear to staff. Use a consistent way to distinguish drafts from finalized reports, and avoid workflows where a draft and final version look identical in the same folder. The goal is not to make corrections impossible. It is to ensure a finalized result cannot be changed as an ordinary save operation.
Access control and auditability are also covered as security concepts in NIST SP 800-53. Use it as a reference, not as an assumption that every control applies to every repair shop; applicability depends on your circumstances and requirements.
Set a correction process that preserves the original
When someone finds an error in a finalized report, do not silently replace the original. Have the employee flag the report and explain the concern. An authorized reviewer can assess whether the issue is a clerical correction, a change to recorded test data, or a reason to perform or review testing again.
If a correction is approved, retain the original report and issue a corrected version or a clearly linked correction record. Mark the corrected document so readers can tell it supersedes or supplements the earlier version. Keep the connection between the original and corrected records, rather than making the new file appear to be the only version that ever existed.
A correction record should identify:
- The report identifier and the location of the original report.
- The reason for the correction and the specific field or information changed.
- The person who requested the change and the person who made it.
- When the correction was made, and who reviewed or authorized it.
- The corrected version or record that is linked to the original.
Where the correction changes a test result rather than a clerical detail, document what supports the change and whether additional testing or review was performed. Avoid making a correction that obscures the measured result. Staff reviewing the job history should be able to understand what was originally recorded and what changed afterward.
Check the setup on the actual test-bench PC
Permissions that look right on paper may not behave as intended in the shop’s software. Test the workflow using accounts with the access technicians and reviewers actually have. Confirm that a technician can create and submit a report, view a finalized report, and cannot overwrite or delete it through the usual software and file paths.
Check that the correction process works too. An authorized reviewer should be able to document a valid change without removing the original, and other staff should be able to find both records. Review access when staff responsibilities change, and periodically verify that finalized reports remain protected.
Backups add another layer of recovery, but they are not a replacement for access controls or a correction history. A backup may help recover a file after loss or damage, while version history and a documented correction process help explain changes. Zevonix describes versioned backups for test results, QA folders, and calibration records. For more on protecting shop records, see its guidance on backup solutions for motor shops.
Test-bench PCs also need careful maintenance so security changes do not disrupt testing. For related guidance, read about updating a test-bench computer without disruption and IT support for motor testing software.
Frequently asked questions
How can a shop make completed motor test reports read-only?
Restrict write and delete access to finalized report folders for ordinary technician accounts, and check that the test application cannot overwrite those files through its own account or workflow. A file’s read-only setting alone may not be enough.
Should technicians have separate user accounts on a test-bench PC?
Yes, individual accounts help associate activity with a person and make it easier to manage access as responsibilities change. Check the test application as well as the PC, since a shared application login can limit traceability.
Who should be allowed to reopen or correct a finalized report?
Assign that responsibility to a designated reviewer or other authorized role. Technicians should have a clear way to request a correction, with approval handled according to the shop’s documented process and any applicable customer requirements.
What should a correction record include?
Record the report identifier, reason for the change, information changed, requester, person making the correction, date, reviewer, and link to the corrected version. Preserve access to the original report.
Protect the result and keep corrections traceable
Preventing accidental edits is a combination of individual accounts, role-based permissions, software checks, and a correction process that keeps the original result visible. Start by reviewing who can write to finalized report folders and whether the test-bench application can bypass those restrictions. If you would like help reviewing IT controls around test-bench PCs and shop data, contact Zevonix at (386) 260-0777.